Pure Steam (Clean Steam) is the purest form of available steam whose condensate should meet all the parameters of Water for Injection (WFI). In general terms, it is defined as steam which is free from all chemicals & biological impurities.


Application –
• WFI System sterilization
• Fermenter sterilization
• CIP/SIP system condensate drainage
• Sterilization of process vessels and pipes
• Culinary systems
• Humidifiers
• Steam barriers (Blocks & Bleed System)


Applicable Codes – ASME BPE
The Uni Klinger make Sanitary steam trap is of balanced pressure design with SS316L bellows capable of releasing condensate within 1°C (2 – 3 °F) of saturated pressure. Clean steam Trap utilizes a hygienic body clamp allowing disassembly for inspection or cleaning and is made up of an entirely self-draining design leading to no condensate retention.


Salient Features

  • High Purity Compliance: Designed for applications requiring pure steam (WFI quality condensate), ideal for sterilization and processes demanding minimal contamination.

  • Balanced Pressure & Efficient Drainage: Ensures condensate removal within a tight temperature range (1°C) of saturated steam, promoting efficient operation in clean steam systems.

  • Hygienic Design & Easy Maintenance: Features a self-draining design with no condensate retention and utilizes a hygienic body clamp for easy disassembly and cleaning, crucial for maintaining sterility.